Enertite spray foam insulation is a low-density, open-cell, spray-applied polyurethane foam insulation for internal roofs, floors, and walls. Applied as a liquid, this BASF manufactured water blown system expands to over 100x its original size completely filling all voids helping to provide an airtight barrier. Enertite spray foam is installed throughout Ireland by a network of local BASF contractors.
Features and benefits
- Quickly applied with no waste, minimum fuse and maximum effect
- Improve energy efficiency and provide barrier against unwanted sounds
- Cost effective option for superior airtight & thermal insulation
- No VOC’s, CFC’s, formaldehyde and has no harmful side effects
- Rapidly expands to 100 times filling voids and sealing your building
- Will not settle of sag and will last lifetime of building
- Installed throughout Ireland by a network of local BASF Foam Masters
- National Standards of Ireland (NSAI) approved
Downloads
ENERTITE® roof insulation
New pitched roof
The open cell spray foam can be cut flush with the adjacent timbers to allow for plasterboard fixing or can be sprayed proud of the roof rafter to the desired thickness.
BASF enertite insulation can be applied to breathable roofing membranes provided a counter-batten is place above the felt covering and below the tile / slate batten in accordance with Irish and UK Building Regulations.
Existing pitched roof
BASF enertite is applied to the required thickness in order to provide a particular level of insulation or U-Value. The open cell spray foam can be cut flush with the adjacent timbers to allow for plasterboard fixing or can be sprayed proud of the roof rafter to the desired thickness.
ENERTITE® wall insulation
Timber frame wall insulation
BASF enertite spray insulation can installed to fully fill the timber studwork and is shaved flush with the inner stud facing prior to the application of the VCL and plasterboard inner lining.
Enertite spray foam insulation is installed by trained and accredited Foam Master contractors. Applied as a liquid, this water blown system expands to over 100 times its original size completely filling all voids help provide an airtight barrier.
Refurbished wall insulation
Mechanical and electrical services can be fixed within the foam material however the use electrical conduit is recommended.
BASF enertite spray insulation can be installed to fully fill the timber studwork and is shaved flush with the inner stud facing prior to the application of the VCL and plasterboard inner lining.
ENERTITE® floor insulation
Attic floor insulation
The open cell spray foam is ordinarily applied to below the uppermost level of ceiling joists. A counter joist can be fixed onto the ceiling joist to allow for a thicker layer if required.